Wisconsin FOG & Grease Trap Rules
Milwaukee
Commercial food establishments must install and maintain grease interceptors. Wisconsin Plumbing Code SPS 382.34(5) governs sizing and requires at least 750 gallons for discharge to municipal sewers under the cited provision. Obtain the applicable municipal plumbing permit and confirm cleaning intervals with Milwaukee’s Department of Neighborhood Services or sewer authority. Keep maintenance records accessible for inspection.